Longer Backup UPS w/o AVR - Low Frequency series
PS 600 LCD & LED, PS 850 LCD & LED & PS 1600 LCD UPS models are ideal for SOHO environment.
- Microcontroller based digital inverter
- Fast change over
- Off mode charging
- Cold Start on battery
- Gen Set compatible
Available in in five models: 600 LCD & LED, 850 LCD & LED & 1600 LCD
Microcontroller based digital inverter
Fast change over
Off mode charging
Cold Start on battery
Gen Set compatible
24 months warranty
Selectable input voltage range (in 850 and 1600)
Runs Home Appliances, Fan, Light and Computer
Selectable Intelligent CVCC Battery Charger (in 850 and 1600)
MOSFET based Battery Reverse protection (in 850 and 1600)
Over load protection with auto restart.
Input over current protection with miniature circuit breaker
Easy to repair Single sided PCB
| PS 600LF | PS 850LF | PS 1600LF | ||
|---|---|---|---|---|
| Capacity VA/W | 600VA | 850VA | 1600VA | |
| Input | ||||
| Voltage Range | 100-300VAC | 170-280VAC (Narrow Range) | ||
| 90-280VAC (Wide Range) | ||||
| Output | ||||
| Voltage Regulation (Bat) | +/- 10% | |||
| Frequency (Bat) | 50Hz +/-1Hz | |||
| Output Waveform (Bat) | Modified Sine Wave | |||
| Battery & Charger | ||||
| DC Bus Voltage | 12V | 24V | ||
| Transfer Time (Typical) | 10ms Typical, 20ms max | |||
| No. of Batteries | One | Two | ||
| Battery Capacity | 65AH to 200AH | 65AH to 200AH | ||
| Charging Current | 10A | Selectable: Low 10A, High 20A | ||
| Battery Reverse Protection | Yes, Fuse Based. Fuse will blow. |
Yes, MOSFET based. No fuse will blow. |
||
| Indicator | ||||
| Display (LED) | 3 LEDs indicating: Mains On, Inverter On, Battery Low, Over Load and Fault | |||
| Display (LCD) | Input & Output Voltage, Battery & Load Level, Mains and Battery mode | |||
| Audible Alarm | ||||
| Low Battery at Battery Mode | Sounding every second | |||
| Overload | Sounding every 0.5 second | |||
| Fault | Continuously Sounding | |||
| Mains Fail or Recover | Beeps once | |||
| Protection | ||||
| Protection | Battery Reverse (fuse), Over Charger, Over Discharge, Over Load | |||
| Physical | ||||
| Dimensions (D x W x H mm) |
359 x 97 x 147 | 288 x 290 x 127 | ||
| Net Weight (kgs) | 4.7 | 7 | 10 | |
| Model | PS 600LF | PS 850LF | PS 1600LF |
|---|---|---|---|
| Option A | 3 Fan, 4 Tube | 4 Fan, 6 Tube | 7 Fan, 8 Tube |
| Option B | 2 Fan, 3 Tube, 1 TV | 3 Fan, 5 Tube, 1 TV | 6 Fan, 7 Tube, 1 TV |
| Option C | 1 Fan, 3 Tube, 1PC | 2 Fan, 3 Tube, 1PC | 5 Fan, 6 Tube, 1PC |